Spacers remote deaf-ends type RG, RGU, 3RG, 4RG, 5RG, 6RG, 8RG
Spacers remote deaf-ends type RG
NOMINATION:
Designed to capture at a given distance of two aluminum, steel-aluminum wire split-phase overhead power lines and outdoor switchgear. Spacers meet TU 34 13.11050-90
Type |
Diameter of wire, mm |
Dimensions, mm |
Weight, kg |
|
d |
L |
|||
RG-2-300 |
21,6-26,6 |
25,0 |
300 |
1,60 |
RG-2-400 |
400 |
1,79 |
||
RG-2-485 |
485 |
1,95 |
||
RG-2-500 |
500 |
1,98 |
||
RG-2-600 |
600 |
2,17 |
||
RG-2-650 |
650 |
2,26 |
||
RG-3-400 |
27,5-30,6 |
30,0 |
400 |
1,79 |
RG-3-500 |
500 |
1,98 |
||
RG-3-600 |
600 |
2,17 |
||
RG-4-400 |
31,5-37,7 |
36,0 |
400 |
1,77 |
RG-4-500 |
500 |
1,96 |
||
RG-4-600 |
600 |
2,15 |
||
RG-6-400 |
59/51,5 |
58,0 |
400 |
2,40 |
_________________________________________________________________________________________________________________
Spacers remote with permanently secured on the wire RGU
Designed to capture at a given distance of two aluminum, steel-aluminum wire split-phase overhead power lines and outdoor switchgear. Spacers RG are different of greater reliability. Spacers meet TU 34 13.11050-90.
|
|
Designation |
Fig. |
Diameter of wire, mm |
Dimensions, mm |
Weight, kg |
||
B |
D |
L |
||||
RGU-0-300 |
1 |
13,0-16,8 |
25 |
16 |
300 |
0,81 |
RGU-1-300 |
17,1-19,8 |
20 |
300 |
0,81 |
||
RGU-0-400 |
13,0-16,8 |
16 |
400 |
1,15 |
||
RGU-1-400 |
17,1-19,8 |
20 |
400 |
1,15 |
||
RGU-0-500 |
13,0-16,8 |
16 |
500 |
1,30 |
||
RGU-1-500 |
17,1-19,8 |
20 |
500 |
1,30 |
||
RGU-2-300 |
21,6-26,6 |
30 |
25 |
300 |
2,11 |
|
RGU-2-400 |
25 |
400 |
2,30 |
|||
RGU-2-485 |
25 |
485 |
2,46 |
|||
RGU-2-500 |
25 |
500 |
2,49 |
|||
RGU-2-600 |
25 |
600 |
2,68 |
|||
RGU-2-650 |
25 |
650 |
2,77 |
|||
RGU-3-400 |
27,5-30,6 |
30 |
400 |
2,26 |
||
RGU-3-500 |
30 |
500 |
2,45 |
|||
RGU-3-600 |
30 |
600 |
2,64 |
|||
RGU-3-650 |
30 |
650 |
2,73 |
|||
RGU-4-400 |
31,5-37,7 |
36 |
400 |
2,22 |
||
RGU-4-500 |
36 |
500 |
2,41 |
|||
RGU-4-600 |
36 |
600 |
2,60 |
|||
RGU-4-650 |
36 |
650 |
2,69 |
|||
RGU-5-400 |
42,4-47,02 |
46 |
400 |
2,57 |
||
RGU-5-600 |
46 |
600 |
2,95 |
|||
RGU-2-850 |
2 |
21,6-26,6 |
Ø 33,5 |
25 |
850 |
3,96 |
RGU-3-850 |
27,5-30,6 |
30 |
850 |
3,92 |
||
RGU-4-850 |
31,5-37,7 |
36 |
850 |
3,88 |
||
RGU-4-970 |
31,5-37,7 |
|
970 |
4,21 |
_________________________________________________________________________________________________________________
Spacers deaf-end three-beam type 3RG
NOMINATION:
Designed to capture at a given distance of three aluminum, steel-aluminum wire split-phase overhead power lines and outdoor switchgear. Spacers meet TU 34 13.10805-92
|
|
Designation |
Diameter of wire, mm |
Dimensions, mm |
Weight, kg |
|
d |
L |
|||
3RG-3-400А |
27,5-30,6 |
30 |
400 |
401 |
3RG-5-1А |
45 |
46 |
400 |
4,55 |
_________________________________________________________________________________________________________________
Spacers remote deaf-ends type 4RG
NOMINATION:
Type |
Diameter of wire, mm |
Dimensions, mm |
Weight, kg |
|
d |
L |
|||
4RG-3-400A |
27.5-30,6 |
30 |
400 |
6.04 |
4RG-3-600A |
600 |
8.24 |
||
4RG-4-400A |
31.5-37.7 |
36 |
400 |
6.0 |
4RG-4-600A |
600 |
8.2 |
||
4RG-6-400 |
59/51.6 |
58 |
400 |
6.8 |
_________________________________________________________________________________________________________________
Spacers death beamed 5RG, 6RG
NOMINATION:
Designed to capture at a given distance of five, six aluminum, steel-aluminum wire split-phase overhead power lines and outdoor switchgear. Spacers meet TU 34 13.11050-90.
|
|
Designation |
Fig. |
Diameter of wire, mm |
Dimensions, mm |
Weight, kg |
||
D |
d |
L |
||||
5RG-2-300А |
1 |
21,6-26,6 |
510 |
25 |
300 |
5,9 |
5RG-2-400А |
21,1-26,6 |
680 |
25 |
400 |
8,4 |
|
5RG-3-400А |
27,5-30,6 |
680 |
30 |
400 |
8,3 |
|
5RG-4-600А |
2 |
37,5 |
1020 |
36 |
600 |
14,81 |
5RG-5-600А |
46,5 |
1020 |
46 |
600 |
15,7 |
|
6RG-5-400 |
3 |
45/37 |
800 |
46 |
400 |
9,46 |
_________________________________________________________________________________________________________________
Spacers remote with permanently secured on the wire 8RG
NOMINATION:
Designed to capture at a given distance of eight aluminum, steel-aluminum wire split-phase overhead power lines and outdoor switchgear. Spacers meet TU 34 13.11050-90.
|
|
Designation |
Fig. |
Diameter of wire, mm |
Dimensions, mm |
Weight, kg |
|
D |
d |
||||
8RG-2-400B |
1 |
21,6-26,6 |
1045 |
25 |
20,8 |
8RG-3-400B |
1 |
27,5-30,6 |
1045 |
30 |
20,6 |
8RG-2-400G |
2 |
21,6-26,6 |
1009 |
25 |
15,1 |